SubjectBlue Star Evidence Packet - Lift Station 27 Upgrades - Due Jul 7, 2026
AttachmentLift Station 27 Upgrades.pdf
[DISTRIBUTOR NAME],
We have a bid opportunity in Friendswood, TX that fits your coverage area. Details below.
Opportunity: Lift Station 27 Upgrades
Contracting Agency: Friendswood, TX
Location: Friendswood, TX
Due Date: Jul 7, 2026
Key Specs: See attached packet for source-backed specifications
The evidence packet is attached as a PDF with the current configuration direction, compliance matrix, and supporting documentation.
Let us know if you have questions or need any changes before submitting.
Best,
[YOUR NAME]
Blue Star Power Systems
CSP 2026 -10 Plan Set - Lift Station 7 Upgrades - page 16Kalluri Group, Inc.
CSP 2026 -10 Plan Set - Lift Station 7 Upgrades - page 15engineering
CSP 2026 -10 Plan Set - Lift Station 7 Upgrades - page 12Consulting Engineering Services
Project Location
AIFriendswood, TX
CSP 2026 -10 Plan Set - Lift Station 7 Upgrades - page 115355 BLACKHAWK BLVD.
CSP 2026 -10 Plan Set - Lift Station 7 Upgrades - page 1CITY OF FRIENDSWOOD, TEXAS LIFT STATION No. 27 UPGRADES
Project Application
AILift Station Upgrade (Wastewater)
CSP 2026 -10 Plan Set - Lift Station 7 Upgrades - page 1LIFT STATION No. 27 UPGRADES
Generator Requirements35
Rating Type / Application
AI—
No source-backed value found
Fuel TypePricing input
AI—
No source-backed value found
Size (kW) + QuantityPricing input
AI—
No source-backed value found
Voltage + PhasePricing input
AIphase: 3 · voltage: 480V
CSP 2026 -10 Plan Set - Lift Station 7 Upgrades - page 22PH A
CSP 2026 -10 Plan Set - Lift Station 7 Upgrades - page 23480V
Alternator Rating / Temp Rise
AI—
No source-backed value found
Voltage Regulator
AI—
No source-backed value found
Generator Space Heater
AI—
No source-backed value found
Control Panel
AI—
No source-backed value found
Control Panel Options / Accessories
AI—
No source-backed value found
Remote Annunciator
AI—
No source-backed value found
Enclosure Type + Material
AI—
No source-backed value found
Sound Attenuation
AI—
No source-backed value found
Enclosure / Auxiliary-Power Accessories
AI—
No source-backed value found
Circuit Breaker(s)
AI—
No source-backed value found
Generator Circuit Breaker
AI—
No source-backed value found
Engine Filters
AI—
No source-backed value found
EPSS Class / Level
AI—
No source-backed value found
Exhaust Connector End Fittings
AI—
No source-backed value found
Generator Control Alarms
AI—
No source-backed value found
Generator Breaker Settings / Trip
AI—
No source-backed value found
Vibration Isolators
AI—
No source-backed value found
Voltage / Frequency Transient Testing
AI—
No source-backed value found
Battery Compartment Heater
AI—
No source-backed value found
Drawing Generator Rating / One-Line
AIOne-line diagram (E-4, p22): 480V service from pad-mounted transformer through meter disconnect and main service disconnect to ATS; Generator is emergency source connected to ATS; ATS feeds control panel and mini power center (MPC). Load table: PUMP NO.1 30HP 40A, PUMP NO.2 30HP 40A, PUMP NO.3 30HP 40A, MISC POWER & CONTROLS 10KVA 21A; Total load 157A/136A/157A on 200A service. Conduit schedule (E-5, p23): Tag 101 ATS Normal Feeder 480V from main service disconnect to ATS; Tag 102 ATS Emergency Feeder 480V from ATS to Generator; Tag 102A Generator Control 24V from ATS to Generator.
CSP 2026 -10 Plan Set - Lift Station 7 Upgrades - page 22EXISTING EQUIPMENT TO REMAIN.
CSP 2026 -10 Plan Set - Lift Station 7 Upgrades - page 23GENERATOR CONTROL
CSP 2026 -10 Plan Set - Lift Station 7 Upgrades - page 23ATS EMERGENCY FEEDER
One-Line Generator Breaker Ratings (spatially connected main and auxiliary breakers)
AILow peak fuse in disconnect to limit available fault current to less than 10KA. Minimum equipment rating 25KAIC. Service capacity 200A per phase.
CSP 2026 -10 Plan Set - Lift Station 7 Upgrades - page 22MINIMUM EQUIPMENT RATING SHALL BE NO LESS THAN 25KAIC
CSP 2026 -10 Plan Set - Lift Station 7 Upgrades - page 22LOW PEAK FUSE TO BE USED IN DISCONNECT TO LIMIT AVAILABLE FAULT CURRENT ON THE EQUIPMENT TO LESS THAN 10KA.