Fuel TypeDiesel (ASTM D-975 Grade No. 2D S15 ultra-low sulfur)Meets
Size (kW) + QuantityLine 1: 3 × 600 kW · diesel · 480V, 3 PH · permanentMeets
Send to distributorEvidence packet attached
Distributor assignment has not been synced for this bid yet.
SubjectBlue Star Evidence Packet - ITB# 202620-Purchase of Three (3) Backup Generators for Wastewater Treatment Plant - Due Jul 2, 2026
AttachmentITB# 202620-Purchase of Three (3) Backup Generators for Wastewater Treatment Plant.pdf
[DISTRIBUTOR NAME], We have a bid opportunity in Homestead, FL that fits your coverage area. Details below. Opportunity: ITB# 202620-Purchase of Three (3) Backup Generators for Wastewater Treatment Plant Contracting Agency: City of Homestead Location: Homestead, FL Due Date: Jul 2, 2026 Key Specs: 3 × PD600-01 The evidence packet is attached as a PDF with the current configuration direction, compliance matrix, and supporting documentation. Let us know if you have questions or need any changes before submitting. Best, [YOUR NAME] Blue Star Power Systems
Copy keeps both HTML and plain text.
Employee review
Review workspace
Loading packet preview...
Review notes
Distributor assignment has not been synced for this bid yet.
Review status
Business bucket
Past due priced
Bid value
$303,674.40
Checks reviewed
0/51 reviewed
Provisional pricing0.48

A Blue Star configuration exists, but it is not an approved opportunity price until review is resolved. The submission deadline has passed; pricing is retained for history.

Found value

$632,655.00

Configurator/list/base price
$632,655.00
Active manual adders
$0.00
Reviewed list/base price
$632,655.00
Distributor net
$303,674.40
3 × PD600-01
600 kW · diesel · $632,655.00
Distributor multiplierControls reviewed net pricing
New manual adderSaved as active reviewer pricing provenance
Active on save
No manual pricing adders have been saved.
Packet regenerationNo generated packet is recorded.
Field checks
51
Add Field Check itemField checks do not change price. Add price impact under Reviewed pricing.
Project Overview3
Engineering Firm

AIHazen and Sawyer

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 38HAZEN AND SAWYER

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 41Hazen and Sawyer 999 Ponce de Leon Boulevard, Suite #1150·Coral Gables, FL 33134

Project Location

AIHomestead, FL

ITB#_202620-Purchase_of_Three_(3)_Backup_Generators_for_Wastewater_Treatment_Plant_(Addendum_#2_Revision).pdf - page 6551 SE 8th Street

ITB#_202620-Purchase_of_Three_(3)_Backup_Generators_for_Wastewater_Treatment_Plant_(Addendum_#2_Revision).pdf - page 6Homestead, FL 33030

Project Application

AIWastewater Treatment Plant

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 2wastewater treatment facility

ITB#_202620-Purchase_of_Three_(3)_Backup_Generators_for_Wastewater_Treatment_Plant_(Addendum_#2_Revision).pdf - page 1BACKUP GENERATORS FOR WASTEWATER TREATMENT PLANT

Generator Requirements35
Rating Type / Application

AIStandby (Class 120, Type 10 per NFPA 110)

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 4Class 120, Type 10 power engine generator sets

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 15standby kW rating shall be for continuous electrical service during interruption of the normal utility source

Fuel TypePricing input

AIDiesel (ASTM D-975 Grade No. 2D S15 ultra-low sulfur)

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 15The engine shall be diesel, 4 cycle

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 15Engine shall operate on ASTM D-975 Grade No. 2D S15 ultra-low sulfur diesel fuel

Size (kW) + QuantityPricing input

AILine 1: 3 × 600 kW · diesel · 480V, 3 PH · permanent

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 4three (3) complete and operable, diesel engine-driven engine generators

WWTP Engine Generators Pre-Purchase Package - OPCC - page 2600kW/750kVA Standby Generator, 480V, 3ph, 4W

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 5All three (3) engine-generators furnished under this Section shall be capable of parallel operation through a master paralleling control system

Voltage + PhasePricing input

AIphase: 3 · voltage: 480V

WWTP Engine Generators Pre-Purchase Package - OPCC - page 2480V, 3ph, 4W

Alternator Rating / Temp Rise

AIClass F insulation, 105°C temperature rise (NEMA); brushless, salient pole, 2/3 pole pitch

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 15Insulation shall be Class F with a temperature rise of no more than 105 degrees C according to NEMA standards

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 15brushless, salient pole, 2/3 pole pitch

Voltage Regulator

AIAdjustable, solid-state, three-phase RMS sensing, volts/hertz type; +/-0.25% regulation; +/-10% voltage adjustment; located within engine control panel

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 16The voltage regulator shall be an adjustable, solid-state, three-phase RMS sensing, volts/hertz type. Voltage regulation shall be a minimum of +/-0.25% from no load to continuous rating. The voltage regulator shall provide +/-10% voltage ad

Generator Space Heater

AIAlternator mounted strip heater, energized when not running to prevent condensation

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 16An alternator mounted strip heater shall be furnished and installed as part of the system. The strip heater shall be energized to prevent condensation when the engine generator set is not running.

Control Panel

AIMicroprocessor-based control panel with LCD display, NEMA 1 (gasketed) dust-tight enclosure

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 17microprocessor-based control panel complete with an LCD display

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 16Engine generator monitoring and controls shall be mounted in a single NEMA 1 (gasketed) dust-tight enclosure.

Control Panel Options / Accessories

AIEngine control mode switch (Run-Off-Auto); large red emergency stop pushbutton; LCD display (12+ parameters); Ethernet/IP communication port; fiber optic connection capability; Form C dry contacts (5A at 120VAC/24VDC) for 10 alarm/status signals; common Generator System Failure alarm

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 18capabilities for fiber optic cable connection

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 18communication port capable of transmitting all available engine-generator set data via Ethernet/IP protocol

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 17Large, red emergency stop pushbutton

Remote Annunciator

AIRemote annunciation of permanent emergency source disconnection via SWBD-GEN contact point; common Generator System Failure alarm for remote indication

B - Low Voltage Switchboards Pre-Purchase Package (SPECS/DRAWINGS) - page 36SWBD-GEN shall include a contact point that shall annunciate at a location remote from the engine-generators to indicate that the permanent emergency source is disconnected from the emergency system.

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 19common "Generator System Failure" alarm for remote indication

Enclosure Type + Material

AIFBC HVHZ approved, sound attenuated, weather-protective; 12-gauge aluminum or 14-gauge galvanized steel

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 26Florida Building Code (FBC) High Velocity Hurricane Zone (HVHZ) approved, sound attenuating, weather-protective housing

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 26constructed of 12-gauge (minimum) aluminum or 14 gauge (minimum) galvanized steel

Sound Attenuation

AILevel 3

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 29The engine-generator enclosure shall provide Level 3 sound attenuation.

Enclosure / Auxiliary-Power Accessories

AICombination power unit (30kVA min, 208/120V, dry type transformer + lighting panelboard); linear LED lighting (20 fc); GFCI convenience receptacles at each door; aluminum stairs and handrails; outdoor LED light fixtures; air intake louvers with rain guards; hinged lockable doors; lifting eyes; 316 stainless steel exterior hardware

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 28Linear LED lighting shall be provided in sufficient quantity to maintain 20 foot-candles

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 2730kVA minimum

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 27Aluminum stairs and aluminum handrail shall be furnished at each door

Circuit Breaker(s)

AI

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 19Circuit breakers shall be insulated case type power circuit breakers.

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 19UL 1066 Listed for application at 100 percent of their continuous current rating, rated 480 VAC, 3 pole

Generator Circuit Breaker

AIInsulated case type power circuit breakers, UL 1066, 480VAC, 3 pole, 100% rated, electrically operated, fixed-mount, with shunt trip, spring charging motor, microprocessor trip unit

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 19Power circuit breakers shall be electrically operated (E.O.).

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 19Power circuit breakers shall be fixed-mount type as indicated on the Drawings.

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 19Circuit breakers shall be insulated case type power circuit breakers.

Engine Filters

AIHeavy duty dry type air filter with restriction indicator; heavy duty lubricating oil filter (bypass type); heavy duty fuel oil filter (spin-on); fuel oil fuel/water separator; heavy duty crankcase vapor coalescer; radiator mounted fuel cooler

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 20Heavy duty lubricating oil filter, bypass type

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 21Fuel oil fuel/water separator

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 21Heavy duty crankcase vapor coalescer

EPSS Class / Level

AIClass 120, Type 10 (NFPA 110)

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 4three (3) Class 120, Type 10 power engine generator sets

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 6NFPA 110-Standard for Emergency and Standby Power Systems.

Exhaust Connector End Fittings

AIStainless steel flexible convoluted exhaust pipe with flange-type connections; taper-cut tail pipe with rain cap; all exterior components 316 stainless steel

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 22taper-cut tail pipe complete with rain cap

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 22All exterior components of the exhaust system shall be made of 316 stainless steel.

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 22stainless steel flexible convoluted exhaust pipe. Use flange-type connections

Generator Control Alarms

AIShutdown: high coolant temp, low oil pressure, low fuel, overspeed, overcrank, fail to start, low coolant; Pre-alarms: pre-high temp, pre-low fuel, low coolant temp; Common Generator System Failure alarm (NC contacts in series); Form C dry contacts for 10 signals

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 18Engine coolant high temperature

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 18Engine low oil pressure

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 18Engine overcrank

Generator Breaker Settings / Trip

AILong-time, short-time, ground fault (adjustable pickup and delay); instantaneous (adjustable pickup with high-fault override); arc energy reduction mode for 1200A+ frames; trip units: Eaton PXR25, Square D Micrologic 5.0X/6.0X, ABB Ekip Touch, or Siemens ETU 776

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 19Long-time, short-time, and ground fault segments shall have both adjustable pickup and

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 20Trip units shall be the Eaton PXR25, Square D Micrologic 5.0X/6.0X, ABB Ekip Touch, or Siemens ETU 776.

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 20arc energy reduction mode

Vibration Isolators

AISeismically-rated spring type isolators

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 29Fasten to the underside of the skids seismically-rated spring type isolators.

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 9Seismically rated vibration isolators

Voltage / Frequency Transient Testing

AINo load to full load: voltage dip ≤35%, frequency dip ≤20%, recovery ≤12 sec; Full load to no load: voltage overshoot ≤7%, recovery ≤3 sec; per ISO 8528

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 16voltage dip of 35%, a frequency dip of 20%, and shall recover to complete steady state performance within 12 seconds

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 16voltage overshoot of 7% and shall recover to steady state performance within 3 seconds

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 16Transient performance shall be in accordance with ISO 8528.

Battery Compartment Heater

AIBattery heating pad, 120VAC or 208VAC

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 22battery heating pad that operates at 120VAC or 208VAC

Drawing Generator Rating / One-Line

AI3 x 600kW/750kVA Standby Generator, 480V, 3ph, 4W (per OPCC); single-line diagrams referenced as E-01 through E-03

WWTP Engine Generators Pre-Purchase Package - OPCC - page 2600kW/750kVA Standby Generator, 480V, 3ph, 4W

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 38DRAWING:E-01

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 38SINGLE-LINE DIAGRAMS

One-Line Generator Breaker Ratings (spatially connected main and auxiliary breakers)

AI

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 19rated 480 VAC, 3 pole

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 39SINGLE LINE DIAGRAM

Jacket Water Heater

AIUnit mounted thermal circulation type coolant heater with recirculation pump, 208VAC, 3-phase, thermostatically controlled, maintains coolant at -20°F ambient

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 21Unit mounted thermal circulation type coolant heater with coolant recirculation pump shall be furnished to maintain engine jacket coolant temperature as recommended by manufacturer in an ambient temperature of minus $ 2 0^{\circ} \mathrm{F}

Exhaust Silencer

AICritical type; 316 stainless steel (exterior mount) or painted steel with calcium silicate insulation and brushed aluminum skin (interior mount); insulation blanket rated 1200°F

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 22Silencers shall be of critical type and sized to produce a high degree of silencing.

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 22painted steel and insulated using a calcium silicate material covered by a brushed aluminum skin

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 22316 stainless steel construction on its interior and exterior

Battery and Battery Charger

AI

No source-backed value found

Fuel Tank + Accessories

AIUL-142 listed base mounted steel tank, 120 hours min capacity; rupture basin and leak detection system with remote alarm contact; pre-low fuel (30 hr) and low fuel level devices; 4-20mA analog remote indication; lockable fill port and level gauge; automatic fill closure at 95%; fill whistle; four spare 2-inch ports

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 26U.L.-142 listed base mounted fuel tank of sufficient capacity to operate the engine-generator set at full load for a minimum of 120 hours

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 26valve that automatically closes the fuel fill inlet when the tank level reaches 95%

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 26Four (4) spare 2-inch (minimum) ports

Factory Testing

AI

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 323 hours - full load

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 32reactive (0.8 power factor) load banks

Field Quality Control / Site Acceptance

AIField load bank tests with resistive (1.0 PF) load banks: 5 hr full load, 1 hr 3/4, 1 hr 1/2, 1 hr 1/4; 4 hr with facility loads; enclosure water tests; control/shutdown/alarm circuit testing; transfer testing with single and multiple generators; data recorded every 15 min

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 335 hours, full load

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 32water tests to confirm the enclosure does not leak

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 33four (4) hours with facility loads

Load Bank

AIRadiator mounted, 200kW, 480VAC, 3-phase, 3-wire, 60Hz, 1.0 PF; Avtron, Simplex, or approved equal; four-step load shedding control with remote NEMA 1A panel

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 30Avtron Manufacturing, Inc., Simplex, Inc., or an equal product

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 29The load bank shall be rated 200kW, and designed for operation at 480VAC, 3-phase, 3wire, 60 Hz, with a 1.0 power factor.

Switchgear / Paralleling

AIThree generators operating in parallel under Master Paralleling Controller (furnished by engine-generator manufacturer); full supervisory, synchronization, and load-sharing functions

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 2The three (3) generators will operate in parallel under the control of a Master Paralleling Controller.

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 5All three (3) engine-generators furnished under this Section shall be capable of parallel operation through a master paralleling control system providing full supervisory, synchronization, and load-sharing functions.

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 5The Master Paralleling Controller shall be furnished by the engine-generator manufacturer

Warranty

AI4 years or 500 hours (whichever first) from delivery, including repair labor, travel, and expendables; batteries: 2-year full + 48-month pro-rated; 2-year minimum preventive maintenance agreement

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 13preventive maintenance agreement using qualified factory trained service personnel, for a period of 2-year minimum

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 12four (4) years or five hundred (500) hours of operation, whichever comes first, from date of delivery of equipment to the project site

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 12Batteries shall be provided with two (2) year full replacement guarantee, and a 48-month pro-rated replacement schedule thereafter.

Generator Overload Capacity

AI300% rated current for 10 seconds (fault clearing via PMG excitation); 2190 SkVA minimum at ≤30% instantaneous voltage dip

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 16enable the alternator to support 300% of rated current for 10 seconds to allow fault clearing

A - Engine Generators Pre-Purchase Package (SPECS/DRAWINGS) - page 152190 SkVA (minimum) at an instantaneous voltage dip of no more than 30% voltage drop

ATS Requirements13
ATS Quantity

AI

B - Low Voltage Switchboards Pre-Purchase Package (SPECS/DRAWINGS) - page 2a distribution switchboard (SWBD-DIST) housing an Automatic Transfer Controller (ATC).

ATS Manufacturer / Model

AI

No source-backed value found

ATS Ratings

AI

No source-backed value found

Transition Type

AI

No source-backed value found

Poles / Neutral Configuration

AI

No source-backed value found

ATS Enclosure Type

AI

No source-backed value found

ATS Features / Accessories

AI

No source-backed value found

ATS Transfer Timing

AI

No source-backed value found

ATS Auxiliary Contacts

AI

No source-backed value found

ATS In-Phase Monitor

AI

No source-backed value found

ATS Engine Exerciser

AI

No source-backed value found

ATS Configuration Schedule (every distinct tagged instance kept separate by page/location, with rating, poles, and service rating)

AI

No source-backed value found

ATS Load Sequencing / Shedding

AI

No source-backed value found

Reviewer verdict & notesdraft
Source DocumentsSource Page
PDF
City_of_Homestead_WWTP_Low_Voltage_Switchboards_Pre-Purchase_Package_(SPECS).pdf
PDF
Grant_I0127_and_Amendment_1%2C_2%2C_3.pdf
PDF
ICE%3A_City_of_Homestead_WWTP_Engine_Generators_Pre-Purchase_Package_-_OPCC.pdf
PDF
City_of_Homestead_WWTP_Engine_Generators_Pre-Purchase_Package_(SPECS_DRAWINGS).pdf
PDF
Independent_Cost_Estimate_(ICE)_REQ_165332.pdf
PDF
ITB%23_202620-Purchase_of_Three_(3)_Backup_Generators_for_Wastewater_Treatment_Plant_(Addendum_%232_Revision).pdf
PDF
5-21-2026_Email_-_Florida_Commerce_approval_to_issue_ITB_202620_ITB_202621.pdf