Past due priced

Calhoun County - REBID Magnolia Beach VFD Building Project

The submission deadline has passed; pricing is retained for history.

Compliance matrix4 checks shown
Field CheckFound ValueStatus
Engineering FirmG & W Engineers, Inc.Meets
Project Location873 Margie Tewmey Road #1 Port Lavaca, Texas 77979Meets
Fuel TypeDieselMeets
Size (kW) + QuantityLine 1: 1 × 130 kW · diesel · 120/208VAC, 3 PH · permanentMeets
Send to distributorEvidence packet attached
Distributor assignment has not been synced for this bid yet.
SubjectBlue Star Evidence Packet - Calhoun County - REBID Magnolia Beach VFD Building Project - Due Jul 14, 2026
AttachmentCalhoun County - REBID Magnolia Beach VFD Building Project.pdf
[DISTRIBUTOR NAME], We have a bid opportunity in Calhoun, TX that fits your coverage area. Details below. Opportunity: Calhoun County - REBID Magnolia Beach VFD Building Project Contracting Agency: G&W Engineers, Inc. Location: Calhoun, TX Due Date: Jul 14, 2026 Key Specs: 1 × JD150-01 The evidence packet is attached as a PDF with the current configuration direction, compliance matrix, and supporting documentation. Let us know if you have questions or need any changes before submitting. Best, [YOUR NAME] Blue Star Power Systems
Copy keeps both HTML and plain text.
Employee review
Review workspace
Loading packet preview...
Review notes
Distributor assignment has not been synced for this bid yet.
Review status
Business bucket
Past due priced
Bid value
$40,084.80
Checks reviewed
29/51 reviewed
Provisional pricing0.48

A Blue Star configuration exists, but it is not an approved opportunity price until review is resolved. The submission deadline has passed; pricing is retained for history.

Found value

$83,510.00

Configurator/list/base price
$83,510.00
Active manual adders
$0.00
Reviewed list/base price
$83,510.00
Distributor net
$40,084.80
1 × JD150-01
130 kW · diesel · $83,510.00
Distributor multiplierControls reviewed net pricing
New manual adderSaved as active reviewer pricing provenance
Active on save
No manual pricing adders have been saved.
Packet regenerationNo generated packet is recorded.
Field checks
51
Add Field Check itemField checks do not change price. Add price impact under Reviewed pricing.
Project Overview3
Engineering Firm

AIG & W Engineers, Inc.

5310.022b - MBVFD - CD - 051226 REBID - page 2Texas Registered Engineering Firm F-04188

5310.022b - MBVFD - CP 031226 REBID - page 3G&W ENGINEERS, INC. HAS PROVIDED THE BID ITEMS

5310.022b - MBVFD - CD - 051226 REBID - page 2G & W ENGINEERS, INC.

Saved
Project Location

AI873 Margie Tewmey Road #1 Port Lavaca, Texas 77979

5310.022b - MBVFD - CD - 051226 REBID - page 1873 Margie Tewmey Road #1 Port Lavaca, Texas 77979

5310.022b - MBVFD - CP 031226 REBID - page 4CALHOUN COUNTY, TEXAS

Saved
Project Application

AIFire Station

5310.022b - MBVFD - CP 031226 REBID - page 7MAGNOLIA BEACH VOLUNTEER FIRE DEPARTMENT

5310.022b - MBVFD - CD - 051226 REBID - page 1REBID MAGNOLIA BEACH FIRE STATION PROJECT

Saved
Generator Requirements35
Rating Type / Application

AIStandby/Prime

5310.022b - MBVFD - CD - 051226 REBID - page 4STANDBY GENERATOR PLATFORM PLAN

5310.022b - MBVFD - CP 031226 REBID - page 39130KW STAND BY, 117KW PRIME

Saved
Fuel TypePricing input

AIDiesel

5310.022b - MBVFD - CD - 051226 REBID - page 19117-kW diesel engine generator

5310.022b - MBVFD - CP 031226 REBID - page 39GEN-1 DIESEL GENERATOR

Saved
Size (kW) + QuantityPricing input

AILine 1: 1 × 130 kW · diesel · 120/208VAC, 3 PH · permanent

5310.022b - MBVFD - CP 031226 REBID - page 39130KW STAND BY, 117KW PRIME, 3-PH, 120/208VAC

5310.022b - MBVFD - CD - 051226 REBID - page 19117-kW diesel engine generator

5310.022b - MBVFD - CP 031226 REBID - page 39GEN-1 DIESEL GENERATOR

Saved
Voltage + PhasePricing input

AIphase: 3 · voltage: 120/208VAC

5310.022b - MBVFD - CP 031226 REBID - page 393-PH, 120/208VAC

Saved
Alternator Rating / Temp Rise

AI

No source-backed value found

Saved
Voltage Regulator

AI

No source-backed value found

Saved
Generator Space Heater

AI

No source-backed value found

Saved
Control Panel

AIConfigured for auto start/auto re-transfer

5310.022b - MBVFD - CP 031226 REBID - page 39CONFIGURED FOR AUTO START/AUTO RE-TRANSFER

Saved
Control Panel Options / Accessories

AI

No source-backed value found

Saved
Remote Annunciator

AI

No source-backed value found

Saved
Enclosure Type + Material

AIWeather-protected enclosure

5310.022b - MBVFD - CP 031226 REBID - page 39WEATHER-PROTECTED ENCLOSURE

Saved
Sound Attenuation

AI

No source-backed value found

Enclosure / Auxiliary-Power Accessories

AI150 MPH wind kit

5310.022b - MBVFD - CP 031226 REBID - page 39150 MPH WIND KIT

Saved
Circuit Breaker(s)

AIGenerator: main line circuit breaker; ATS-1: 600A main breaker, service entrance rated; MDP: 600A main breaker; LRP-1/2/3: 225A MLO

5310.022b - MBVFD - CP 031226 REBID - page 39MAIN LINE CIRCUIT BREAKER

5310.022b - MBVFD - CP 031226 REBID - page 39225A MLO

5310.022b - MBVFD - CP 031226 REBID - page 39SERVICE ENTRANCE RATED, MAIN BREAKER

Saved
Generator Circuit Breaker

AIMain line circuit breaker

5310.022b - MBVFD - CP 031226 REBID - page 39MAIN LINE CIRCUIT BREAKER

Engine Filters

AI

No source-backed value found

EPSS Class / Level

AI

No source-backed value found

Exhaust Connector End Fittings

AI

No source-backed value found

Generator Control Alarms

AI

No source-backed value found

Generator Breaker Settings / Trip

AI

No source-backed value found

Vibration Isolators

AI

No source-backed value found

Voltage / Frequency Transient Testing

AI

No source-backed value found

Battery Compartment Heater

AI

No source-backed value found

Drawing Generator Rating / One-Line

AIGEN-1: 130KW standby, 117KW prime, 3-ph, 120/208VAC, diesel, Generac SD130 or eq.

5310.022b - MBVFD - CP 031226 REBID - page 39130KW STAND BY, 117KW PRIME, 3-PH, 120/208VAC

5310.022b - MBVFD - CP 031226 REBID - page 40ELECTRICAL ONE LINE

5310.022b - MBVFD - CP 031226 REBID - page 39GENERAC SD130 OR EQ.

One-Line Generator Breaker Ratings (spatially connected main and auxiliary breakers)

AIGEN-1: main line circuit breaker (no rating specified); ATS-1: 600A, 3-pole, main breaker, service entrance rated; MDP: 600A main breaker; LRP-1/2/3: 225A MLO

5310.022b - MBVFD - CP 031226 REBID - page 39MAIN LINE CIRCUIT BREAKER

5310.022b - MBVFD - CP 031226 REBID - page 39225A MLO

5310.022b - MBVFD - CP 031226 REBID - page 39SERVICE ENTRANCE RATED, MAIN BREAKER

Jacket Water Heater

AI

No source-backed value found

Saved
Exhaust Silencer

AI

No source-backed value found

Saved
Battery and Battery Charger

AI2.5A battery charger

5310.022b - MBVFD - CP 031226 REBID - page 392.5A BATTERY CHARGER

Saved
Fuel Tank + Accessories

AI220-gallon UL 142 approved diesel tank with mechanical fuel gauge

5310.022b - MBVFD - CD - 051226 REBID - page 19220-gallon UL 142 approved fuel tank

5310.022b - MBVFD - CP 031226 REBID - page 39220 GALLON DIESEL TANK, MECH. FUEL GAUGE

Saved
Factory Testing

AI

No source-backed value found

Saved
Field Quality Control / Site Acceptance

AI

No source-backed value found

Load Bank

AI

No source-backed value found

Saved
Switchgear / Paralleling

AI

No source-backed value found

Saved
Warranty

AI12 months from date of final acceptance of the work

5310.022b - MBVFD - CD - 051226 REBID - page 318For a period of one year from date of final acceptance of work covered by this section

5310.022b - MBVFD - CD - 051226 REBID - page 5812 months from the date of final acceptance of the work

Saved
Generator Overload Capacity

AI

No source-backed value found

ATS Requirements13
ATS Quantity

AIquantity: 1 · required: Yes · instances: tag: ATS-1 · rating: 600A, 208/120V, 3-pole

5310.022b - MBVFD - CP 031226 REBID - page 39ATS-1 AUTOMATIC TRANSFER SWITCH

5310.022b - MBVFD - CD - 051226 REBID - page 6automatic transfer switch

5310.022b - MBVFD - CP 031226 REBID - page 393-POLE, 600A, 208/120, OPEN TRANSITION

Saved
ATS Manufacturer / Model

AIEaton ATC3C2C30600BRU or eq.

5310.022b - MBVFD - CP 031226 REBID - page 39EATON TYPE ATC3C2C30600BRU OR EQ.

ATS Ratings

AI600A, 208/120V, 3-pole

5310.022b - MBVFD - CP 031226 REBID - page 393-POLE, 600A, 208/120, OPEN TRANSITION

Saved
Transition Type

AIOpen transition

5310.022b - MBVFD - CP 031226 REBID - page 39OPEN TRANSITION

Poles / Neutral Configuration

AI3-pole

5310.022b - MBVFD - CP 031226 REBID - page 393-POLE, 600A, 208/120, OPEN TRANSITION

Saved
ATS Enclosure Type

AINEMA 3R

5310.022b - MBVFD - CP 031226 REBID - page 39CONTACTOR BASED, NEMA 3R,

Saved
ATS Features / Accessories

AIService entrance rated, main breaker, contactor based

5310.022b - MBVFD - CP 031226 REBID - page 39CONTACTOR BASED, NEMA 3R,

5310.022b - MBVFD - CP 031226 REBID - page 39SERVICE ENTRANCE RATED, MAIN BREAKER

Saved
ATS Transfer Timing

AI

No source-backed value found

ATS Auxiliary Contacts

AI

No source-backed value found

ATS In-Phase Monitor

AI

No source-backed value found

ATS Engine Exerciser

AI

No source-backed value found

ATS Configuration Schedule (every distinct tagged instance kept separate by page/location, with rating, poles, and service rating)

AIATS-1: 600A, 208/120V, 3-pole, service entrance rated, main breaker, open transition, contactor based, NEMA 3R, Eaton ATC3C2C30600BRU or eq.

5310.022b - MBVFD - CP 031226 REBID - page 39ATS-1 AUTOMATIC TRANSFER SWITCH

5310.022b - MBVFD - CP 031226 REBID - page 39EATON TYPE ATC3C2C30600BRU OR EQ.

5310.022b - MBVFD - CP 031226 REBID - page 39CONTACTOR BASED, NEMA 3R,

ATS Load Sequencing / Shedding

AI

No source-backed value found

Reviewer verdict & notesneeds_correction
Source DocumentsSource Page
PDF
5310.022b%20Rebid%20Magnolia%20Beach%20VFD%20Station%20-CD%20051226.pdf
PDF
MBVFD%20Pre-Bid%20Sign%20In%20Sheet%206.11.2026.pdf
PDF
5310.022b%20Magnolia%20Beach%20VFD%20Station%20-%20CP%20Thru%20Rev%201%20031226%20-%20REBID%20Stamp.pdf