DOUGLAS COUNTY FLEET MAINTENANCE GENERATOR PROJECT

Compliance matrix4 checks shown
Field CheckFound ValueStatus
Engineering FirmReview
Project LocationDouglasville, GA 30134Meets
Fuel TypeDieselMeets
Size (kW) + QuantityLine 1: 1 × 100 kW · diesel · 277/480V, 3 PH · permanentMeets
Send to distributorFormal proposal attached
Distributor assignment has not been synced for this bid yet.
SubjectBlue Star Formal Proposal - DOUGLAS COUNTY FLEET MAINTENANCE GENERATOR PROJECT - Due Aug 3, 2026
AttachmentDOUGLAS COUNTY FLEET MAINTENANCE GENERATOR PROJECT.pdf
[DISTRIBUTOR NAME], We have a bid opportunity in Douglas County Board Of Commissioners, GA that fits your coverage area. Details below. Opportunity: DOUGLAS COUNTY FLEET MAINTENANCE GENERATOR PROJECT Contracting Agency: DOUGLAS COUNTY BOARD OF COMMISSIONERS Location: Douglas County Board Of Commissioners, GA Due Date: Aug 3, 2026 Key Specs: 1 × JD100-01 The formal proposal is attached as a PDF with the current configuration direction, compliance matrix, and supporting documentation. Let us know if you have questions or need any changes before submitting. Best, [YOUR NAME] Blue Star Power Systems
Copy keeps both HTML and plain text.
Employee review
Review workspace
Loading packet preview...
Review notes
Distributor assignment has not been synced for this bid yet.
Review status
Business bucket
Priced
Bid value
$32,901.60
Checks reviewed
0/51 reviewed
Reviewed pricing0.48
Found value

$68,545.00

Configurator/list/base price
$68,545.00
Active manual adders
$0.00
Reviewed list/base price
$68,545.00
Distributor net
$32,901.60
1 × JD100-01
100 kW · diesel · $68,545.00
Distributor multiplierControls reviewed net pricing
New manual adderSaved as active reviewer pricing provenance
Active on save
No manual pricing adders have been saved.
Packet regenerationNo generated packet is recorded.
Field checks
51
Add Field Check itemField checks do not change price. Add price impact under Reviewed pricing.
Project Overview3
Engineering Firm

AI

No source-backed value found

Project Location

AIDouglasville, GA 30134

Fleet Generator RFP Draft.pdf - page 18480 DORRIS RD DOUGLASVILLE,GA 30134

Project Application

AIFleet Maintenance Building

Fleet Generator RFP Draft.pdf - page 3The Fleet Maintenance Building serves all Douglas County Departments daily and is home to numerous county employees.

Generator Requirements35
Rating Type / Application

AIStandby; NFPA 110, Level 1, Type 10

Fleet Generator RFP Draft.pdf - page 17NFPA 110, Level 1, Type 10 (10-second start time)

Fleet Generator RFP Draft.pdf - page 3100kW Diesel Standby Generator

Fuel TypePricing input

AIDiesel

Fleet Generator RFP Draft.pdf - page 3100kW Diesel Standby Generator

Size (kW) + QuantityPricing input

AILine 1: 1 × 100 kW · diesel · 277/480V, 3 PH · permanent

Fleet Generator RFP Draft.pdf - page 17factory-assembled 100kW diesel engine-driven generator set

Fleet Generator RFP Draft.pdf - page 17100kW/125kVA at 0.8 power factor.

Voltage + PhasePricing input

AIphase: 3 · voltage: 277/480V

Fleet Generator RFP Draft.pdf - page 17277/480V, 3-phase, 4-wire, 60Hz

Alternator Rating / Temp Rise

AI

No source-backed value found

Voltage Regulator

AI

No source-backed value found

Generator Space Heater

AI

No source-backed value found

Control Panel

AINFPA 110 compliant digital controller with AutoStart/stop and safety shutdowns (high coolant temp, low oil pressure, overspeed)

Fleet Generator RFP Draft.pdf - page 17NFPA 110 compliant digital controller with AutoStart/stop and safety shutdowns (high coolant temp, low oil pressure, overspeed).

Control Panel Options / Accessories

AIIntegrated Ethernet Cellular gateway for remote status alerts (E-mail/SMS) and Modbus integration for Building Automation Systems

Fleet Generator RFP Draft.pdf - page 18Integrated Ethernet Cellular gateway for remote status alerts (E-mail/SMS) and Modbus integration for Building Automation Systems.

Remote Annunciator

AI

No source-backed value found

Enclosure Type + Material

AILevel 2 Sound Attenuated (weatherproof) enclosure

Fleet Generator RFP Draft.pdf - page 17Level 2 Sound Attenuated (weatherproof) enclosure

Sound Attenuation

AILevel 2 Sound Attenuated; maximum 72 dB(A) at 23 feet (7 meters) in a free field

Fleet Generator RFP Draft.pdf - page 17Level 2 Sound Attenuated (weatherproof) enclosure. Maximum sound pressure level shall not exceed 72 dB(A) at 23 feet (7 meters) in a free field.

Enclosure / Auxiliary-Power Accessories

AI

No source-backed value found

Circuit Breaker(s)

AI

No source-backed value found

Generator Circuit Breaker

AI

No source-backed value found

Engine Filters

AI

No source-backed value found

EPSS Class / Level

AINFPA 110, Level 1, Type 10 (10-second start time)

Fleet Generator RFP Draft.pdf - page 17NFPA 110, Level 1, Type 10 (10-second start time)

Exhaust Connector End Fittings

AI

No source-backed value found

Generator Control Alarms

AISafety shutdowns: high coolant temp, low oil pressure, overspeed; electronic "low fuel" and "leak detected" alarms

Fleet Generator RFP Draft.pdf - page 17safety shutdowns (high coolant temp, low oil pressure, overspeed)

Fleet Generator RFP Draft.pdf - page 17electronic "low fuel" and "leak detected" alarms

Generator Breaker Settings / Trip

AI

No source-backed value found

Vibration Isolators

AI

No source-backed value found

Voltage / Frequency Transient Testing

AI

No source-backed value found

Battery Compartment Heater

AI

No source-backed value found

Drawing Generator Rating / One-Line

AI

No source-backed value found

One-Line Generator Breaker Ratings (spatially connected main and auxiliary breakers)

AI

No source-backed value found

Jacket Water Heater

AI

No source-backed value found

Exhaust Silencer

AI

No source-backed value found

Battery and Battery Charger

AI15 Amp, 12 Volt, 50/60 Hz battery charger; Genset Starting Battery 12VDC

Fleet Generator RFP Draft.pdf - page 17Genset Starting Battery 12VDC

Fleet Generator RFP Draft.pdf - page 1715 Amp, 12 Volt, 50/60 Hz battery charger

Fuel Tank + Accessories

AI250-gallon, double walled, sub-base fuel tank; mechanical fuel gauge; electronic "low fuel" and "leak detected" alarms

Fleet Generator RFP Draft.pdf - page 17250-gallon, double walled, sub-base fuel tank

Fleet Generator RFP Draft.pdf - page 17mechanical fuel gauge, electronic "low fuel" and "leak detected" alarms

Factory Testing

AI

No source-backed value found

Field Quality Control / Site Acceptance

AICertificate of Compliance stating the installation meets all local seismic, wind-load, and NFPA 110 Level 1 standards

Fleet Generator RFP Draft.pdf - page 19Certificate of Compliance stating the installation meets all local seismic, wind-load, and NFPA 110 Level 1 standards as required by the grant's mitigation goals.

Load Bank

AI

No source-backed value found

Switchgear / Paralleling

AI

No source-backed value found

Warranty

AI4-hour on-site response time for emergency warranty repairs

Fleet Generator RFP Draft.pdf - page 21guarantee a 4-hour on-site response time for emergency warranty repairs

Generator Overload Capacity

AI

No source-backed value found

ATS Requirements13
ATS Quantity

AIquantity: 1 · required: Yes · instances: tag: — · rating: 400A, NEMA 3R

Fleet Generator RFP Draft.pdf - page 17Automatic Transfer Switch (ATS)

Fleet Generator RFP Draft.pdf - page 17400A, NEMA 3R

ATS Manufacturer / Model

AI

No source-backed value found

ATS Ratings

AI400A

Fleet Generator RFP Draft.pdf - page 17Rating: 400A, NEMA 3R

Transition Type

AI

No source-backed value found

Poles / Neutral Configuration

AI3 Pole

Fleet Generator RFP Draft.pdf - page 173 Pole, silver-alloy contacts, and microprocessor controlled

ATS Enclosure Type

AINEMA 3R

Fleet Generator RFP Draft.pdf - page 17Rating: 400A, NEMA 3R

ATS Features / Accessories

AIIn-phase monitor to prevent motor damage during transfer; programmable plant exerciser (with and without load); 15 Amp, 12 Volt, 50/60 Hz battery charger; Auxiliary Relay-Switch in Emergency Position 12VDC; Auxiliary Relay-Switch in Normal Position 12VDC; Genset Starting Battery 12VDC

Fleet Generator RFP Draft.pdf - page 17In-phase monitor to prevent motor damage during transfer: programmable plant exerciser (with and without load). 15 Amp, 12 Volt, 50/60 Hz battery charger, Auxiliary Relay-Switch in Emergency Position 12VDC, Auxiliary Relay-Switch in Normal

ATS Transfer Timing

AI

No source-backed value found

ATS Auxiliary Contacts

AIAuxiliary Relay-Switch in Emergency Position 12VDC; Auxiliary Relay-Switch in Normal Position 12VDC

Fleet Generator RFP Draft.pdf - page 17Auxiliary Relay-Switch in Emergency Position 12VDC, Auxiliary Relay-Switch in Normal Position 12VDC

ATS In-Phase Monitor

AIIn-phase monitor to prevent motor damage during transfer

Fleet Generator RFP Draft.pdf - page 17In-phase monitor to prevent motor damage during transfer

ATS Engine Exerciser

AIProgrammable plant exerciser (with and without load)

Fleet Generator RFP Draft.pdf - page 17programmable plant exerciser (with and without load)

ATS Configuration Schedule (every distinct tagged instance kept separate by page/location, with rating, poles, and service rating)

AI

No source-backed value found

ATS Load Sequencing / Shedding

AI

No source-backed value found

Reviewer verdict & notesdraft
Source DocumentsSource Page
PDF
202606/supportingdocs/PE-64800-NONST-2026-000000079-2026-06-29_15_12_98-2f4688ac-f1e1-49ab-8409-fcc30212c7e7.pdf
PDF
202607/supportingdocs/PE-64800-NONST-2026-000000079-2026-07-07_09_33_10-e5bb9601-cc8c-4b6f-b7c6-62d3fa1b1f14.pdf
PDF
202606/supportingdocs/PE-64800-NONST-2026-000000079-2026-06-29_15_12_05-6b4a50ad-a5bd-4517-8c6a-9d1f9d3d4967.pdf
PDF
202606/supportingdocs/PE-64800-NONST-2026-000000079-2026-06-29_15_12_84-6bd0cd4c-74cc-4b15-a244-a5362506a3a8.pdf
PDF
202606/supportingdocs/PE-64800-NONST-2026-000000079-2026-06-29_15_12_01-18ab22b9-5a20-44b6-87b1-780d5a5061a4.pdf
PDF
202606/supportingdocs/PE-64800-NONST-2026-000000079-2026-06-29_15_12_00-5b1231f6-024f-4be3-bd21-23e7a6b53fd4.pdf
PDF
202606/supportingdocs/PE-64800-NONST-2026-000000079-2026-06-29_15_12_03-47d68149-d420-45eb-bc49-e5de9339d6ef.pdf
PDF
202606/supportingdocs/PE-64800-NONST-2026-000000079-2026-06-29_15_12_01-0e92cc89-1b1a-4cd9-81e1-ad61da7b504a.pdf
PDF
202606/supportingdocs/PE-64800-NONST-2026-000000079-2026-06-29_15_12_97-39030051-d5a6-431d-934b-17c8411ce77c.pdf
PDF
202606/supportingdocs/PE-64800-NONST-2026-000000079-2026-06-29_15_12_03-039747bc-df18-44f6-a421-21b09c81d2a5.pdf