Priced

26-6999 Emergency Generator Replacement Project

Compliance matrix4 checks shown
Field CheckFound ValueStatus
Engineering FirmReview
Project LocationCobb County Adult Detention Center, 1825 County Services Parkway, Marietta, GA 30008Meets
Fuel TypeDieselMeets
Size (kW) + QuantityLine 1: 1 × 600 kW · Diesel · 277Y/480V, 3 PH · permanentMeets
Send to distributorFormal proposal attached
Distributor assignment has not been synced for this bid yet.
SubjectBlue Star Formal Proposal - 26-6999 Emergency Generator Replacement Project - Due Jul 23, 2026
Attachment26-6999 Emergency Generator Replacement Project.pdf
[DISTRIBUTOR NAME], We have a bid opportunity in Marietta, GA that fits your coverage area. Details below. Opportunity: 26-6999 Emergency Generator Replacement Project Contracting Agency: COBB COUNTY Location: Marietta, GA Due Date: Jul 23, 2026 Key Specs: 1 × PD600-01 The formal proposal is attached as a PDF with the current configuration direction, compliance matrix, and supporting documentation. Let us know if you have questions or need any changes before submitting. Best, [YOUR NAME] Blue Star Power Systems
Copy keeps both HTML and plain text.
Employee review
Review workspace
Loading packet preview...
Review notes
Distributor assignment has not been synced for this bid yet.
Review status
Business bucket
Priced
Bid value
$112,168.80
Checks reviewed
0/51 reviewed
Reviewed pricing0.48
Found value

$233,685.00

Configurator/list/base price
$233,685.00
Active manual adders
$0.00
Reviewed list/base price
$233,685.00
Distributor net
$112,168.80
1 × PD600-01
600 kW · Diesel · $233,685.00
Distributor multiplierControls reviewed net pricing
New manual adderSaved as active reviewer pricing provenance
Active on save
No manual pricing adders have been saved.
Packet regenerationNo generated packet is recorded.
Field checks
51
Add Field Check itemField checks do not change price. Add price impact under Reviewed pricing.
Project Overview3
Engineering Firm

AI

No source-backed value found

Project Location

AICobb County Adult Detention Center, 1825 County Services Parkway, Marietta, GA 30008

Emergency_Generator_Replacement_Project.pdf - page 1Cobb County Adult Detention Center 1825 County Services Parkway, Power Plant, Marietta, GA 30008

Project Application

AIEmergency generator replacement at Cobb County Sheriff Department Adult Detention Center

Emergency_Generator_Replacement_Project.pdf - page 1Emergency Generator Replacement Project Cobb County Sheriff Department

Generator Requirements35
Rating Type / Application

AIStandby Rated

Emergency_Generator_Replacement_Project.pdf - page 2600KW Standby Rated Emergency Generator

Fuel TypePricing input

AIDiesel

Emergency_Generator_Replacement_Project.pdf - page 2Diesel Powered Engine

Size (kW) + QuantityPricing input

AILine 1: 1 × 600 kW · Diesel · 277Y/480V, 3 PH · permanent

Emergency_Generator_Replacement_Project.pdf - page 2MPS - Parallel Unit

Emergency_Generator_Replacement_Project.pdf - page 2277Y/480V 3 Phase 4 Wire

Emergency_Generator_Replacement_Project.pdf - page 2Diesel Powered Engine

Voltage + PhasePricing input

AIphase: 3 · voltage: 277Y/480V

Emergency_Generator_Replacement_Project.pdf - page 2277Y/480V 3 Phase 4 Wire

Alternator Rating / Temp Rise

AI

No source-backed value found

Voltage Regulator

AI

No source-backed value found

Generator Space Heater

AI

No source-backed value found

Control Panel

AIPowerZone Digital Controller NFPA-110 Compliant Controller designed to be backwards compatible with Generac's Program Manager System Controller

Emergency_Generator_Replacement_Project.pdf - page 2PowerZone Digital Controller NFPA-110 Compliant Controller designed to be backwards compatible with Generac's Program Manager System Controller

Control Panel Options / Accessories

AIRemote E Stop Station

Emergency_Generator_Replacement_Project.pdf - page 2Remote E Stop Station

Remote Annunciator

AIRemote Annunciator

Emergency_Generator_Replacement_Project.pdf - page 3Remote Annunciator installation

Emergency_Generator_Replacement_Project.pdf - page 2Remote Annunciator

Enclosure Type + Material

AIOutdoor Factory Level 2 Sound-Attenuated Enclosure - Aluminum Construction

Emergency_Generator_Replacement_Project.pdf - page 2Outdoor Factory Level 2 Sound-Attenuated Enclosure - Aluminum Construction

Sound Attenuation

AILevel 2 Sound-Attenuated

Emergency_Generator_Replacement_Project.pdf - page 2Level 2 Sound-Attenuated

Enclosure / Auxiliary-Power Accessories

AIAC/DC LED Lighting Kit; Door Alarm Switch Kit; Load Center - 12 Position 1PH

Emergency_Generator_Replacement_Project.pdf - page 2AC/DC LED Lighting Kit, Door Alarm Switch Kit

Emergency_Generator_Replacement_Project.pdf - page 2Load Center - 12 Position 1PH

Circuit Breaker(s)

AI100% Rated Single Mainline Circuit Breaker - 1000A with electronic trip

Emergency_Generator_Replacement_Project.pdf - page 2100% Rated Single Mainline Circuit Breaker - 1000A with electronic trip

Generator Circuit Breaker

AI100% Rated Single Mainline Circuit Breaker - 1000A with electronic trip

Emergency_Generator_Replacement_Project.pdf - page 2100% Rated Single Mainline Circuit Breaker - 1000A with electronic trip

Engine Filters

AI

No source-backed value found

EPSS Class / Level

AI

No source-backed value found

Exhaust Connector End Fittings

AI

No source-backed value found

Generator Control Alarms

AIGround Fault Annunciator

Emergency_Generator_Replacement_Project.pdf - page 2Ground Fault Annunciator

Generator Breaker Settings / Trip

AI

No source-backed value found

Vibration Isolators

AI

No source-backed value found

Voltage / Frequency Transient Testing

AI

No source-backed value found

Battery Compartment Heater

AI

No source-backed value found

Drawing Generator Rating / One-Line

AI

No source-backed value found

One-Line Generator Breaker Ratings (spatially connected main and auxiliary breakers)

AI

No source-backed value found

Jacket Water Heater

AIEngine block heater

Emergency_Generator_Replacement_Project.pdf - page 2Engine block heater

Exhaust Silencer

AI

No source-backed value found

Battery and Battery Charger

AIBattery Charger; Generator Battery and Control Batteries

Emergency_Generator_Replacement_Project.pdf - page 2Generator Battery and Control Batteries

Emergency_Generator_Replacement_Project.pdf - page 2Battery Charger

Fuel Tank + Accessories

AISub-Base Fuel Tank, UL 142 Listed Secondary Containment, 2200 Gallon Capacity Tank, Normal and Emergency Vent Package, Leak Detection Monitor, Fuel level indication; 50-Gallon day tank

Emergency_Generator_Replacement_Project.pdf - page 2Leak Detection Monitor

Emergency_Generator_Replacement_Project.pdf - page 2UL 142 Listed Secondary Containment

Emergency_Generator_Replacement_Project.pdf - page 22200 Gallon Capacity Tank

Factory Testing

AIFactory test reports; Factory Start-Up Services

Emergency_Generator_Replacement_Project.pdf - page 4Factory test reports

Emergency_Generator_Replacement_Project.pdf - page 3Factory Start-Up Services

Field Quality Control / Site Acceptance

AIStartup by manufacturer-certified technician; Four-hour load-bank test at specified load levels; ATS operational testing; Final commissioning report; Owner training session; On site load bank testing per NFPA-110 Chapter 7 (New Installations)

Emergency_Generator_Replacement_Project.pdf - page 4ATS operational testing

Emergency_Generator_Replacement_Project.pdf - page 4Four-hour load-bank test at specified load levels

Emergency_Generator_Replacement_Project.pdf - page 4Startup by manufacturer-certified technician

Load Bank

AIOn site load bank testing per NFPA-110 Chapter 7 (New Installations); Four-hour load-bank test at specified load levels

Emergency_Generator_Replacement_Project.pdf - page 4Four-hour load-bank test at specified load levels

Emergency_Generator_Replacement_Project.pdf - page 3On site load bank testing per NFPA-110 Chapter 7 (New Installations)

Switchgear / Paralleling

AIMPS - Parallel Unit (Generac Modular Power System)

Emergency_Generator_Replacement_Project.pdf - page 2MPS - Parallel Unit

Warranty

AIManufacturer's 5 Year Comprehensive Warranty; Generator manufacturer's warranty: Minimum 5 years or 2,000 operating hours; Contractor workmanship warranty: Minimum 1 year

Emergency_Generator_Replacement_Project.pdf - page 4Generator manufacturer's warranty: Minimum 5 years or 2,000 operating hours.

Emergency_Generator_Replacement_Project.pdf - page 4Contractor workmanship warranty: Minimum 1 year.

Emergency_Generator_Replacement_Project.pdf - page 3Manufacturer's 5 Year Comprehensive Warranty

Generator Overload Capacity

AI

No source-backed value found

ATS Requirements13
ATS Quantity

AI

No source-backed value found

ATS Manufacturer / Model

AI

No source-backed value found

ATS Ratings

AI

No source-backed value found

Transition Type

AI

No source-backed value found

Poles / Neutral Configuration

AI

No source-backed value found

ATS Enclosure Type

AI

No source-backed value found

ATS Features / Accessories

AI

No source-backed value found

ATS Transfer Timing

AI

No source-backed value found

ATS Auxiliary Contacts

AI

No source-backed value found

ATS In-Phase Monitor

AI

No source-backed value found

ATS Engine Exerciser

AI

No source-backed value found

ATS Configuration Schedule (every distinct tagged instance kept separate by page/location, with rating, poles, and service rating)

AI

No source-backed value found

ATS Load Sequencing / Shedding

AI

No source-backed value found

Reviewer verdict & notesdraft
Source DocumentsSource Page
PDF
Emergency_Generator_Replacement_Project.pdf
PDF
Payment_Bond.pdf
PDF
Sample_Contract.pdf
PDF
Performance_Bond.pdf
PDF
SUBCONTRACTOR_AFFIDAVIT_%26_AGREEMENT.pdf