AIKluber Architects + Engineers
A - Detailed Specifications - Fire Station 7 EM Generator - page 2ARCHITECT / ENGINEER KLUBER ARCHITECTS + ENGINEERS 41 W. BENTON STREET AURORA, ILLINOIS 60506
The submission deadline has passed; pricing is retained for history.
| Field Check | Found Value | Status |
|---|---|---|
| Engineering Firm | Kluber Architects + Engineers | Meets |
| Project Location | 1380 Aurora Avenue, Naperville, Illinois 60540 | Meets |
| Fuel Type | Diesel | Meets |
| Size (kW) + Quantity | Line 1: 1 × 150 kW · diesel · 208Y/120, 3 PH · permanent; Line 2: 1 × 75 kW · diesel · temporary | Meets |
A Blue Star configuration exists, but it is not an approved opportunity price until review is resolved. The submission deadline has passed; pricing is retained for history.
$83,510.00
AIKluber Architects + Engineers
A - Detailed Specifications - Fire Station 7 EM Generator - page 2ARCHITECT / ENGINEER KLUBER ARCHITECTS + ENGINEERS 41 W. BENTON STREET AURORA, ILLINOIS 60506
AI1380 Aurora Avenue, Naperville, Illinois 60540
A - Detailed Specifications - Fire Station 7 EM Generator - page 2FIRE STATION #7 EM GENERATOR 1380 AURORA AVENUE NAPERVILLE, ILLINOIS 60540
AIFire Station emergency/standby power
A - Detailed Specifications - Fire Station 7 EM Generator - page 7Project Name: FIRE STATION #7 EM GENERATOR.
A - Detailed Specifications - Fire Station 7 EM Generator - page 1051. Application: Emergency/standby.
AIStandby, Emergency/standby
A - Detailed Specifications - Fire Station 7 EM Generator - page 1052. Power Rating: 150 kW, standby.
A - Detailed Specifications - Fire Station 7 EM Generator - page 1051. Application: Emergency/standby.
AIDiesel
A - Detailed Specifications - Fire Station 7 EM Generator - page 1051. Type: Diesel (compression ignition).
A - Detailed Specifications - Fire Station 7 EM Generator - page 107Fuel Source: Diesel, ASTM D975 No. 2-D or approved cold weather diesel blends.
AILine 1: 1 × 150 kW · diesel · 208Y/120, 3 PH · permanent; Line 2: 1 × 75 kW · diesel · temporary
A - Detailed Specifications - Fire Station 7 EM Generator - page 105Voltage: 208Y/120 V, 3 phase, 60 Hz.
A - Detailed Specifications - Fire Station 7 EM Generator - page 105Power Rating: 150 kW, standby.
A - Detailed Specifications - Fire Station 7 EM Generator - page 7Contractor to provide temporary 75kW diesel generator for duration of construction from start of demolition of existing generator until final acceptance of new generator set.
AIphase: 3 · voltage: 208Y/120
A - Detailed Specifications - Fire Station 7 EM Generator - page 105Voltage: 208Y/120 V, 3 phase, 60 Hz.
AIComply with UL 2200; Insulation System NEMA MG 00001, Class H
A - Detailed Specifications - Fire Station 7 EM Generator - page 109C. Temperature Rise: Comply with UL 2200.
A - Detailed Specifications - Fire Station 7 EM Generator - page 109D. Insulation System: NEMA MG 00001, Class H; suitable for alternator temperature rise.
AIBrushless PMG excitation; generator-mounted volts per Hertz exciter-regulator; voltage regulation +/- one percent from no load to full load; PMG short-circuit current support 300 percent for 10 seconds
A - Detailed Specifications - Fire Station 7 EM Generator - page 1091. Exciter Type: Brushless; provide permanent magnet generator (PMG) excitation system; selfexcited (shunt) systems are not permitted.
A - Detailed Specifications - Fire Station 7 EM Generator - page 1092. PMG Excitation Short-Circuit Current Support: Capable of sustaining 300 percent of rated output current for 10 seconds.
A - Detailed Specifications - Fire Station 7 EM Generator - page 109G. Voltage Regulation: Include generator-mounted volts per Hertz exciter-regulator to match engine and generator characteristics, with voltage regulation +/- one percent from no load to full load
AI—
No source-backed value found
AIMicroprocessor-based control system; unit-mounted, vibration isolated
A - Detailed Specifications - Fire Station 7 EM Generator - page 109A. Provide microprocessor-based control system for automatic control, monitoring, and protection of generator set.
A - Detailed Specifications - Fire Station 7 EM Generator - page 1091. Control Panel Mounting: Unit-mounted unless otherwise indicated; vibration isolated.
AIAutomatic/Manual/Reset/Emergency Stop modes; cycle cranking; programmable time delays; voltage adjustment +/-5%; push-to-test indicator lamps; 3-1/2 inch dial meters with phase selector switch for voltage and current; frequency, real power, reactive power, apparent power, power factor, duty level, engine speed, battery voltage, oil pressure, coolant temperature, run time indications; event log; remote monitoring via PC; auxiliary relay 3PDT; lamp test; common alarm contacts
A - Detailed Specifications - Fire Station 7 EM Generator - page 109a. Automatic Mode: Initiates generator set start/shutdown upon receiving corresponding signal from any automatic transfer switc (ATS1, ATS2 and ATS3).
A - Detailed Specifications - Fire Station 7 EM Generator - page 1115. Other Control Panel Features: a. Event log. b. Remote monitoring capability via PC.
A - Detailed Specifications - Fire Station 7 EM Generator - page 110i. Push-to-test indicator lamps, one each for low oil pressure, high water temperature, overspeed, and overcrank.
AIWall-mounted; flush-mounted for finished areas, surface-mounted for non-finished areas; NFPA 110 indications; audible alarm with silence function; lamp test
A - Detailed Specifications - Fire Station 7 EM Generator - page 111b. Provide audible alarm with silence function.
A - Detailed Specifications - Fire Station 7 EM Generator - page 1111. Remote Annunciator Mounting: Wall-mounted; Provide flush-mounted annunciator for finished areas and surface-mounted annunciator for non-finished areas unless otherwise indicated.
AIAlternator enclosure: NEMA MG 00001, drip-proof
A - Detailed Specifications - Fire Station 7 EM Generator - page 109E. Enclosure: NEMA MG 00001, drip-proof.
AICritical grade or better exhaust silencer; sound attenuation not less than basis of design; generator set sound level test data required
A - Detailed Specifications - Fire Station 7 EM Generator - page 103a. Include generator set sound level test data.
A - Detailed Specifications - Fire Station 7 EM Generator - page 1093. Exhaust Silencer: Provide critical grade or better exhaust silencer with sound attenuation not less than basis of design
AI—
No source-backed value found
AIMain line circuit breaker: thermal magnetic, NEMA AB 1 molded case, integral thermal and instantaneous magnetic trip in each pole, battery-voltage operated shunt trip; panelboard breakers UL 489; enclosed safety switches UL 98 heavy duty; fuses Class RK1 time-delay
A - Detailed Specifications - Fire Station 7 EM Generator - page 1054. Main Line Circuit Breaker: a. Type: Thermal magnetic.
A - Detailed Specifications - Fire Station 7 EM Generator - page 106a. NEMA AB 1 molded case circuit breaker on generator output with integral thermal and instantaneous magnetic trip in each pole; sized in accordance with ANSI/NFPA 70. Include battery-voltage operated shunt trip, connection to open circuit
AIThermal magnetic; NEMA AB 1 molded case; integral thermal and instantaneous magnetic trip in each pole; battery-voltage operated shunt trip; factory-installed line side connections; mounted in enclosure to meet ANSI/NEMA 250
A - Detailed Specifications - Fire Station 7 EM Generator - page 1054. Main Line Circuit Breaker: a. Type: Thermal magnetic.
A - Detailed Specifications - Fire Station 7 EM Generator - page 1066. Main Line Circuit Breakers: Provide factory-installed line side connections with suitable lugs for load side connections. a. NEMA AB 1 molded case circuit breaker on generator output with integral thermal and instantaneous magnetic trip
AILube oil filter, intake air filter (replaceable dry element), fuel filter(s) with water separator; two additional sets of each fuel, oil, and air filter element required for maintenance
A - Detailed Specifications - Fire Station 7 EM Generator - page 104c. Provide two additional sets of each fuel, oil, and air filter element required for the engine generator system.
A - Detailed Specifications - Fire Station 7 EM Generator - page 107Engine Fuel Supply: Provide engine-driven, positive displacement fuel pump with replaceable fuel filter(s), water separator
A - Detailed Specifications - Fire Station 7 EM Generator - page 106J. Engine Accessories: Lube oil filter, intake air filter, lube oil cooler, gear-driven water pump.
AINFPA 110 Level 1, Type 10
A - Detailed Specifications - Fire Station 7 EM Generator - page 1063. Start Time: Capable of starting and achieving conditions necessary for load acceptance within 10 seconds (NFPA 110, Type 10).
A - Detailed Specifications - Fire Station 7 EM Generator - page 1042. NFPA 110 (Standard for Emergency and Standby Power Systems); meet requirements for Level 1 system.
AIFlexible connector (approved) for coupling engine to exhaust system; flanged multiple corrugated stainless steel multi-ply expansion joints with liners; Class 150 slip-on forged steel flanges per ASME B16.5; ASTM A181 Grade I; ASME B16.21 composition ring gaskets
A - Detailed Specifications - Fire Station 7 EM Generator - page 77B. Flexible joints: 1. Provide flanged, multiple, corrugated, stainless steel (multi-ply) expansion joints with liners between exhaust manifold and exhaust piping to absorb thermal expansion and vibration.
A - Detailed Specifications - Fire Station 7 EM Generator - page 771) Class 150, slip-on, forged steel welding flanges in accordance with ASME B16.5.
A - Detailed Specifications - Fire Station 7 EM Generator - page 1082. Engine Exhaust Connection: Provide suitable, approved flexible connector for coupling engine to exhaust system.
AIOvercrank (shutdown); low coolant temperature (warning); high coolant temperature (warning and shutdown); low oil pressure (warning and shutdown); overspeed (shutdown); low fuel level (warning); low coolant level (warning/shutdown); generator control not in automatic (warning); high/low battery voltage (warning); low cranking voltage (warning); battery charger failure (warning); high/low AC voltage (shutdown); high/low frequency (shutdown); overcurrent (shutdown); local and remote common alarm contacts
A - Detailed Specifications - Fire Station 7 EM Generator - page 1101) Overcrank (shutdown). 2) Low coolant temperature (warning). 3) High coolant temperature (warning). 4) High coolant temperature (shutdown). 5) Low oil pressure (warning). 6) Low oil pressure (shutdown). 7) Overspeed (shutdown).
A - Detailed Specifications - Fire Station 7 EM Generator - page 1115) Overcurrent (shutdown). c. Provide contacts for local and remote common alarm.
AITrip rating: select according to generator set rating; integral thermal and instantaneous magnetic trip in each pole; battery-voltage operated shunt trip to open on engine failure; sized per ANSI/NFPA 70
A - Detailed Specifications - Fire Station 7 EM Generator - page 106b. Trip Rating: Select according to generator set rating.
A - Detailed Specifications - Fire Station 7 EM Generator - page 106a. NEMA AB 1 molded case circuit breaker on generator output with integral thermal and instantaneous magnetic trip in each pole; sized in accordance with ANSI/NFPA 70. Include battery-voltage operated shunt trip, connection to open circuit
AISpring-type vibration isolators; mounted on structural steel base and concrete pad; spring isolators also for exhaust silencer
B - Drawings - Fire Station 7 EM Generator - page 2202 INSTALL SILENCER FOR ENGINE EXHAUST. SILENCER FURNISHED BY GENERATOR MANUFACTURER. PROVIDE WITH 3. 202 INSTALL SILENCER FOR ENGINE EXHAUST. SILENCER FURNISHED BY GENERATOR MANUFACTURER. PROVIDE WITH SPRING ISOLATORS.
A - Detailed Specifications - Fire Station 7 EM Generator - page 106L. Mounting: Provide unit with suitable spring-type vibration isolators and mount on structural steel base and concrete pad.
AIFactory: transient and steady state voltage and frequency performance tested. Field: voltage and frequency verified during load tests per NFPA 110 (1.5 hour building load test + 2 hour full load test); recordings at 20-minute intervals of kW, amps, voltage, coolant temp, room temp, oil pressure, frequency
A - Detailed Specifications - Fire Station 7 EM Generator - page 1136. Perform load tests in accordance with NFPA 110 (1.5 hour building load test followed by 2 hour full load test). a. During test, record the following at 20 minute intervals: 1) Kilowatts. 2) Amperes. 3) Voltage. 4) Coolant temperature. 5)
A - Detailed Specifications - Fire Station 7 EM Generator - page 1113. Transient and steady state voltage and frequency performance.
AI—
No source-backed value found
AI—
A - Detailed Specifications - Fire Station 7 EM Generator - page 6E600 ELECTRICAL SINGLE LINE DIAGRAM
B - Drawings - Fire Station 7 EM Generator - page 4REFER TO SINGLE LINE, SHEET E800
AI—
B - Drawings - Fire Station 7 EM Generator - page 4REFER TO SINGLE LINE, SHEET E800
AIEngine mounted, thermostatically controlled, water jacket heater; sized as recommended by equipment supplier; heater voltage as required
A - Detailed Specifications - Fire Station 7 EM Generator - page 106K. Coolant heater: Engine mounted, thermostatically controlled, water jacket heater. The heater shall be sized as recommended by the equipment supplier. Heater voltage shall be as required.
A - Detailed Specifications - Fire Station 7 EM Generator - page 1083. Coolant Heater: Provide thermostatically controlled coolant heater to improve starting under cold ambient conditions
AICritical grade or better; sound attenuation not less than basis of design; furnished by generator manufacturer; select per manufacturer recommendations
A - Detailed Specifications - Fire Station 7 EM Generator - page 1093. Exhaust Silencer: Provide critical grade or better exhaust silencer with sound attenuation not less than basis of design; select according to manufacturer's recommendations to meet sound performance requirements, where specified.
B - Drawings - Fire Station 7 EM Generator - page 2SILENCER FURNISHED BY GENERATOR MANUFACTURER.
AIDual rate battery charger, automatic float and equalize modes, minimum 10 amps; UL 1236 listed; integral overcurrent protection; current limited during cranking; reverse polarity protection; integral DC ammeter and voltmeter; alarm output contacts; trickle type; battery type: lead-acid; battery rack, cables, connectors provided
A - Detailed Specifications - Fire Station 7 EM Generator - page 107a. Battery Type: Lead-acid.
A - Detailed Specifications - Fire Station 7 EM Generator - page 1084. Battery Charger: a. Provide dual rate battery charger with automatic float and equalize charging modes and minimum rating of 10 amps
A - Detailed Specifications - Fire Station 7 EM Generator - page 108c. Listed as complying with UL 1236.
AISeparately mounted double-wall day tank with secondary containment; UL 142 listed; fuel transfer pump(s), valves, automatic controls; compatible with existing Tramont System 2000 ECM; capacity for minimum 4 hours at 100% rated load; alarms: low fuel level, critical low fuel level, high fuel level, critical high fuel level; direct reading fuel level gauge; normal atmospheric vent; emergency pressure relief vent; reuse existing underground fuel tank
A - Detailed Specifications - Fire Station 7 EM Generator - page 1071) Compatible with existing fuel storage system: Tramont System 2000 ECM with day tank demand.
A - Detailed Specifications - Fire Station 7 EM Generator - page 107Reuse existing underground fuel tank from existing generator.
A - Detailed Specifications - Fire Station 7 EM Generator - page 107a. Provide separately mounted double-wall day tank with secondary containment, with fuel transfer pump(s), valves, and automatic controls suitable for operation in the configuration to be installed; listed and labeled as complying with UL 1
AIProduction tests at factory: operation at rated load and rated power factor; single step load pick-up; transient and steady state voltage and frequency performance; operation of safety shutdowns; certified test report included with submittals
A - Detailed Specifications - Fire Station 7 EM Generator - page 111B. Perform production tests on generator sets at factory to verify operation and performance characteristics prior to shipment. Include certified test report with submittals.
A - Detailed Specifications - Fire Station 7 EM Generator - page 1111. Operation at rated load and rated power factor. 2. Single step load pick-up. 3. Transient and steady state voltage and frequency performance. 4. Operation of safety shutdowns.
AIAcceptance test per NFPA 110; 1.5 hour building load test followed by 2 hour full load test; recordings at 20-minute intervals; verify starting/load acceptance, voltage, frequency, phase sequence, control system, safety shutdowns, auxiliary equipment; test alarm and shutdown circuits by simulation; NETA ATS inspection for ATS; ground resistance max 5 ohms; manufacturer's representative required for start-up
A - Detailed Specifications - Fire Station 7 EM Generator - page 113G. Perform acceptance test in accordance with NFPA 110.
A - Detailed Specifications - Fire Station 7 EM Generator - page 113b. Test alarm and shutdown circuits by simulating conditions.
A - Detailed Specifications - Fire Station 7 EM Generator - page 1136. Perform load tests in accordance with NFPA 110 (1.5 hour building load test followed by 2 hour full load test).
AIExisting permanent load bank salvaged to owner; new dual purpose docking station for portable generator and load bank connection provided; load bank and fuel provided by contractor for field testing
B - Drawings - Fire Station 7 EM Generator - page 4SALVAGE EXISTING PERMANENT LOAD BANK AND TURN OVER TO OWNER. DEMOLISH ALL ASSOCIATED FEEDERS AND CONTROLLERS BACK TO SOURCE.
A - Detailed Specifications - Fire Station 7 EM Generator - page 113D. Provide all equipment, tools, and supplies required to accomplish inspection and testing, including load bank and fuel.
B - Drawings - Fire Station 7 EM Generator - page 4PROVIDE NEW DUAL PURPOSE DOCKING STATION FOR PORTABLE GENERATOR AND LOADBANK CONNECTION, REFER TO SPECIFICATIONS.
AISingle packaged engine generator set operated independently (not in parallel)
A - Detailed Specifications - Fire Station 7 EM Generator - page 1052. Configuration: Single packaged engine generator set operated independently (not in parallel).
AIMinimum one year manufacturer warranty covering repair or replacement due to defective materials or workmanship; one year contractor guarantee from date of final acceptance and final payment; one year service and maintenance of generator system
FIRE_STATION_7_GENERATOR_REPLACEMENT_(Addendum_#1_Revision).pdf - page 25the Contractor shall unconditionally guarantee the materials and workmanship on all materials, items and work furnished under this contract, including contract changes and additions FOR A PERIOD OF ONE YEAR from date of final acceptance and
A - Detailed Specifications - Fire Station 7 EM Generator - page 105B. Provide minimum one year manufacturer warranty covering repair or replacement due to defective materials or workmanship.
AIPMG excitation short-circuit current support: 300 percent of rated output current for 10 seconds; maximum load step: 100 percent of rated load in one step
A - Detailed Specifications - Fire Station 7 EM Generator - page 1092. PMG Excitation Short-Circuit Current Support: Capable of sustaining 300 percent of rated output current for 10 seconds.
A - Detailed Specifications - Fire Station 7 EM Generator - page 1064. Maximum Load Step: Supports 100 percent of rated load in one step.
AIquantity: 3 · required: Yes · instances: tag: ATS1 · rating: —; tag: ATS2 · rating: —; tag: ATS3 · rating: —
A - Detailed Specifications - Fire Station 7 EM Generator - page 1211. ATS1: Transfer within 10 seconds 2. ATS2 and ATS3: Transfer within 1 minute. 3. ATS3 (ELEVATOR TEST MODE): Transfer within 10 seconds.
A - Detailed Specifications - Fire Station 7 EM Generator - page 109a. Automatic Mode: Initiates generator set start/shutdown upon receiving corresponding signal from any automatic transfer switc (ATS1, ATS2 and ATS3).
B - Drawings - Fire Station 7 EM Generator - page 4PROVIDE NEW ATS-1, COORDINATE CONSTRUCTION WITH OWNER TO LIMIT DOWNTIME, REFER TO SINGLE LINE FOR MORE INFORMATION.
AIBasis of Design: Schneider Electric; ASCO 7000 Series. Other acceptable: ABB, Eaton, Generac, Rehlko
A - Detailed Specifications - Fire Station 7 EM Generator - page 1171. ABB: www.electrification.us.abb.com/#sle. 2. Eaton Corporation: www.eaton.com/#sle. 3. Generac Power Systems: www.generac.com/industrial/#sle. 4. Rehlko: www.powersystems.rehlko.com/#sle. 5. Schneider Electric; ASCO Power Technologies: w
A - Detailed Specifications - Fire Station 7 EM Generator - page 117D. Basis of Design - Automatic Transfer Switch: Schneider Electric; ASCO 7000 Series:
AIFrame: 150 A to 600 A; Voltage: 208 V; Ampere Rating: as indicated on drawings
A - Detailed Specifications - Fire Station 7 EM Generator - page 118f. Voltage: 208 V.
A - Detailed Specifications - Fire Station 7 EM Generator - page 118e. Ampere Rating: As indicated on drawings.
A - Detailed Specifications - Fire Station 7 EM Generator - page 117a. Frame: 150 A to 600 A.
AIOpen transition
A - Detailed Specifications - Fire Station 7 EM Generator - page 117b. Transition Configuration: Open transition.
AIThree phase poles; solid neutral
A - Detailed Specifications - Fire Station 7 EM Generator - page 117c. Neutral Configuration: Solid neutral.
A - Detailed Specifications - Fire Station 7 EM Generator - page 117d. Phase Poles: Three.
AI—
A - Detailed Specifications - Fire Station 7 EM Generator - page 121M. Enclosure: ICS 10, Type 1, finished with manufacturer's standard gray enamel.
AIBypass/isolation switches (overlapping make-before-break); elevator test switch; three position selector switch (AUTO, OFF, TEST); indicating lights (NORMAL SOURCE AVAILABLE, ALTERNATE SOURCE AVAILABLE, SWITCH POSITION, NORMAL BYPASS, ALTERNATE SOURCE BYPASS); green lamp (normal), red lamp (emergency); frequency/voltage relay; disconnect plug on wiring harness; return to normal switch; normal source monitor; alternate source monitor; bypass/isolation operation (normal, test, isolate modes)
A - Detailed Specifications - Fire Station 7 EM Generator - page 120B. Elevator Test Switch: Mount in cover of enclosure to simulate failure of normal source.
A - Detailed Specifications - Fire Station 7 EM Generator - page 120A. Indicating Lights: Mount in cover of enclosure to indicate NORMAL SOURCE AVAILABLE, ALTERNATE SOURCE AVAILABLE, SWITCH POSITION, NORMAL BYPASS, and ALTERNATE SOURCE BYPASS.
A - Detailed Specifications - Fire Station 7 EM Generator - page 1182. Bypass/Isolation Switch Type: Provide overlapping (make-before-break) switches with no interruption of power to load.
AIATS1: transfer within 10 seconds; ATS2 and ATS3: transfer within 1 minute; ATS3 elevator test mode: transfer within 10 seconds; time delay to start engine generator: 0-10 seconds adjustable; time delay before transfer to alternate: 0-60 seconds adjustable; time delay before transfer to normal: 0-30 minutes adjustable; time delay before engine shutdown: 0-30 minutes adjustable
A - Detailed Specifications - Fire Station 7 EM Generator - page 1211. ATS1: Transfer within 10 seconds 2. ATS2 and ATS3: Transfer within 1 minute. 3. ATS3 (ELEVATOR TEST MODE): Transfer within 10 seconds.
A - Detailed Specifications - Fire Station 7 EM Generator - page 121B. Time Delay To Start Alternate Source Engine Generator: 0 to 10 seconds, adjustable.
A - Detailed Specifications - Fire Station 7 EM Generator - page 121F. Time Delay Before Transfer to Normal Power: 0 to 30 minutes, adjustable; bypass time delay in event of alternate source failure.
AIMain shaft auxiliary contact rated 10 ampere at 240V (one closed on normal, one closed on emergency); transfer switch auxiliary contacts: 1 normally open, 1 normally closed
A - Detailed Specifications - Fire Station 7 EM Generator - page 120F. Main shaft auxiliary contact rated ten (10) ampere at 240V (one closed on normal and one closed on emergency).
A - Detailed Specifications - Fire Station 7 EM Generator - page 120H. Transfer Switch Auxiliary Contacts: 1 normally open; 1 normally closed.
AIInphase monitor: permits transfer when phase voltages are within 15 degrees and two cycles; if source supplying load fails or drops below 70 percent, permits immediate transfer
A - Detailed Specifications - Fire Station 7 EM Generator - page 120K. Inphase Monitor: Monitors normal and emergency sources and permits transfer when phase voltages are 15 degrees and two (2) cycles. If the source supplying the load fails or drops below 70 percent, the monitor will permit immediate transf
AIStart engine every 7 days; run for 30 minutes before shutting down; bypass exerciser control if normal source fails during exercising period
A - Detailed Specifications - Fire Station 7 EM Generator - page 121H. Engine Exerciser: Start engine every 7 days; run for 30 minutes before shutting down. Bypass exerciser control if normal source fails during exercising period.
AI—
B - Drawings - Fire Station 7 EM Generator - page 4REFER TO SINGLE LINE, SHEET E800
AILoad shedding contacts (2 NO and 2 NC) operating from adjustable 0.6-60 seconds prior to transfer in either direction; resets 0.6-60 seconds after transfer
A - Detailed Specifications - Fire Station 7 EM Generator - page 121L. Load shedding contacts (2 NO and 2 NC) that operates from an adjustable 0.6 -60 seconds prior to transfer in either direction and resets .6 - 60 seconds after transfer.